Origin of Biomedical Signals

The biomedical signals differ from other signals only in terms of the application — signals that are used in the biomedical field. As such, biomedical signals are produced from a variety of sources. The following is a brief description of these sources:

1. Bioelectric signals: The bioelectric signal is unique to biomedical systems. It is produced by nerve cells and muscle cells. It is produced due to the membrane potential, which under certain conditions may be excited to generate an action potential. In single-cell measurements, the specific microelectrodes are used as sensors, and the action potential itself is considered as the biomedical signal. In more gross measurements, the surface electrodes are used as sensors, and the electric field generated by the action of many cells, distributed in the electrode’s vicinity, constitutes the bioelectric signal. Bioelectric signals are probably the foremost biosignals. The fact that most biosystems use excitable cells makes it possible, to use biosignals to study and monitor the main functions of the systems. The electric field propagates through the biological medium, and thus the potential may be acquired at relatively convenient locations on the surface, eliminating the need to invade the system. The bioelectric signal is acquired by a relatively simple transducer. A transducer is required in the field of biomedical because the electric conduction in the biomedical medium is executed through ions, while the conduction in the measurement system is executed through electrons. All these lead to the fact that the bioelectric signal is broadly used in most of the fields of biomedicine.

2. Bioimpedance signals: The impedance of the tissue contains important information related to its composition, blood volume, blood distribution, endocrine activity, autonomic nervous system activity, and many more. The bioimpedance signal is usually generated by injecting into the tissue under test sinusoidal currents (frequency range of $50 kHz–1 MHz$, with low current densities of the order of $20–20 mA$). The electrode polarization problems are minimized by choosing the frequency range and the low current densities are selected to prevent tissue damage mainly due to heating effects. Bioimpedance measurements are usually performed with four electrodes. Two electrodes (known as source electrodes) are used to inject the current into the tissue and these electrodes are connected to a current source. Remaining two electrodes (known as measuring electrodes) are placed on the tissue under investigation and used to measure the voltage drop generated by the current and the tissue impedance.

3. Bioacoustic signals: Many biomedical phenomena create acoustic noise. The measurement of this acoustic noise gives information about the underlying phenomenon. The flow of blood in the heart (i.e through the heart’s valves, or through blood vessels) generates typical acoustic noise. The flow of air through the upper and lower airways and in the lungs generates acoustic sounds. These sounds are called coughs, snores, and chest and lung sounds. These sounds are used extensively in medicine. Sounds are also produced in the digestive tract and in the joints. It also has been observed that the contracting muscle generates an acoustic noise or muscle noise. Since the acoustic energy propagates through the biological medium, the bioacoustic signal may be conveniently acquired on the surface, using acoustic transducers (microphones or accelerometers).

4. Biomagnetic signals: Many organs, such as the brain, heart, and lungs, produce extremely weak magnetic fields. The measurements of these fields provide information but are not included in other biosignals (such as bioelectric signals). Due to the low level of the magnetic fields to be measured, biomagnetic signals are usually of a very low signal-to-noise ratio. Extreme precautions must be taken in designing or developing the acquisition system of these signals.

5. Biomechanical signals: The term biomechanical signals includes all signals used in the biomedicine fields that originate from some mechanical function of the biological system. These signals include motion and displacement signals, pressure and tension signals, flow signals, and others. The measurement of bio-mechanical signals requires a variety of transducers, not always simple and inexpensive. The mechanical phenomenon does not propagate in biomedical signals, as do the electric, magnetic, and acoustic fields. Hence the measurement usually has to be performed at the exact site. This very frequently complex the measurement and forces it to be an invasive one.

6. Biochemical signals: The chemical measurements from the living tissue or from samples analyzed in the clinical laboratory produce biochemical signals. Measuring the concentration of various ions inside and around a cell using specific ion electrodes. It is an example of such a signal. Partial pressures of oxygen (pO2) and carbon dioxide (pCO2) in the blood or respiratory system are other examples. Biochemical signals are often very low-frequency signals. Mostly, biochemical signals are actually DC signals.

7. Biooptical signals: Bio-optical signals are the result of optical functions of the biological system, occurring naturally or induced by the measurement. Blood oxygenation may be analyzed by measuring the transmitted and backscattered light from a tissue ( i.e.in vivo and in vitro) in several wavelengths. Important information about the fetus may be acquired by measuring the fluorescence characteristics of the amniotic fluid. Analysis of the Heart output may be performed by the dye dilution method, which requires the observation of the appearance of recirculated dye in the bloodstream. The development of fiberoptic technology has opened vast applications of bio-optical signals.

Comments

Popular Posts

Numerical Aperture and Acceptance Angle of the Optical Fibre

Angle of Acceptance → If incident angle of light on the core for which the incident angle on the core-cladding interface equals the critical angle then incident angle of light on the core is called the "Angle of Acceptance. Transmission of light when the incident angle is equal to the acceptance angle If the incident angle is greater than the acceptance angle i.e. $\theta_{i}>\theta_{0}$ then the angle of incidence on the core-cladding interface will be less than the critical angle due to which part of the incident light is transmitted into cladding as shown in the figure below Transmission of light when the incident angle is greater than the acceptance angle If the incident angle is less than the acceptance angle i.e. $\theta_{i}<\theta_{0}$ then the angle of incidence on the core-cladding interface will be greater than the critical angle for which total internal reflection takes place inside the core. As shown in the figure below Transmission of lig

Fraunhofer diffraction due to a single slit

Let $S$ be a point monochromatic source of light of wavelength $\lambda$ placed at the focus of collimating lens $L_{1}$. The light beam is incident normally from $S$ on a narrow slit $AB$ of width $e$ and is diffracted from it. The diffracted beam is focused at the screen $XY$ by another converging lens $L_{2}$. The diffraction pattern having a central bright band followed by an alternative dark and bright band of decreasing intensity on both sides is obtained. Analytical Explanation: The light from the source $S$ is incident as a plane wavefront on the slit $AB$. According to Huygens's wave theory, every point in $AB$ sends out secondary waves in all directions. The undeviated ray from $AB$ is focused at $C$ on the screen by the lens $L_{2}$ while the rays diffracted through an angle $\theta$ are focussed at point $p$ on the screen. The rays from the ends $A$ and $B$ reach $C$ in the same phase and hence the intensity is maximum. Fraunhofer diffraction due to

Particle in one dimensional box (Infinite Potential Well)

Let us consider a particle of mass $m$ that is confined to one-dimensional region $0 \leq x \leq L$ or the particle is restricted to move along the $x$-axis between $x=0$ and $x=L$. Let the particle can move freely in either direction, between $x=0$ and $x=L$. The endpoints of the region behave as ideally reflecting barriers so that the particle can not leave the region. A potential energy function $V(x)$ for this situation is shown in the figure below. Particle in One-Dimensional Box(Infinite Potential Well) The potential energy inside the one -dimensional box can be represented as $\begin{Bmatrix} V(x)=0 &for \: 0\leq x \leq L \\ V(x)=\infty & for \: 0> x > L \\ \end{Bmatrix}$ $\frac{d^{2} \psi(x)}{d x^{2}}+\frac{2m}{\hbar^{2}}(E-V)\psi(x)=0 \qquad(1)$ If the particle is free in a one-dimensional box, Schrodinger's wave equation can be written as: $\frac{d^{2} \psi(x)}{d x^{2}}+\frac{2mE}{\hbar^{2}}\psi(x)=0$ $\frac{d^{2} \psi(x)}{d x